{"product_id":"ubiquiti-u7-industrial-access-point","title":"Ubiquiti U7 Industrial Access Point","description":"\u003cp\u003e\u003cstrong\u003eUbiquiti U7 Industrial Access Point\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIP67 industrial WiFi 7 access point with extended-temperature operation, integrated high-gain directional RF system with adjustable isolation and beamwidth control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003csub\u003e\u003cb\u003e\u003cstrong class=\"lexical-bold lexical-subscript\"\u003eNote\u003c\/strong\u003e\u003c\/b\u003e\u003cspan class=\"lexical-subscript\"\u003e. Requires UniFi Network 11 RC and Access Point 8.8.12 (expected Oct 12).\u003c\/span\u003e\u003c\/sub\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color tutor-markdown-rendering\" id=\"model-response-message-contentr_467a0b4fc3494d1a\" dir=\"ltr\"\u003e\n\u003ctable data-path-to-node=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,1,0,0\"\u003e\u003cb data-path-to-node=\"0,1,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,1,1,0\"\u003e\u003cb data-path-to-node=\"0,1,1,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Device: 170 × 103 × 41.2 mm (6.7 × 4.1 × 1.6\")\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,1,2,1\"\u003e\n\u003cdiv\u003e• Ball mount installed: 170 × 103 × 107.6 mm (6.7 × 4.1 × 4.2\")\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,1,2,3\"\u003e\n\u003cdiv\u003e• Adjustable reflectors installed: 177.6 × 299.7 × 177.8 mm (7 × 11.8 × 7\")\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,1,2,5\"\u003e\n\u003cdiv\u003e• Omnidirectional antennas installed: 341.8 × 103 × 107.6 mm (13.5 × 4.1 × 4.2\")\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,2,1,0\"\u003e\u003cb data-path-to-node=\"0,2,1,0\" data-index-in-node=\"0\"\u003eWiFi Standard\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,2,2,0\"\u003eWiFi 7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,3,1,0\"\u003e\u003cb data-path-to-node=\"0,3,1,0\" data-index-in-node=\"0\"\u003eSpatial Streams\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,3,2,0\"\u003e4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,4,1,0\"\u003e\u003cb data-path-to-node=\"0,4,1,0\" data-index-in-node=\"0\"\u003eCoverage Area\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,4,2,0\"\u003e465 m² (5,000 ft²)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,5,1,0\"\u003e\u003cb data-path-to-node=\"0,5,1,0\" data-index-in-node=\"0\"\u003eMax. Client Count\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,5,2,0\"\u003e200+\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,6,1,0\"\u003e\u003cb data-path-to-node=\"0,6,1,0\" data-index-in-node=\"0\"\u003eUplink\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,6,2,0\"\u003e2.5 GbE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,7,1,0\"\u003e\u003cb data-path-to-node=\"0,7,1,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,7,2,0\"\u003eWall, Pole (Mounts included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,8,1,0\"\u003e\u003cb data-path-to-node=\"0,8,1,0\" data-index-in-node=\"0\"\u003eWeatherproofing\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,8,2,0\"\u003eIP67\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,9,1,0\"\u003e\u003cb data-path-to-node=\"0,9,1,0\" data-index-in-node=\"0\"\u003ePower Method\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,9,2,0\"\u003ePoE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,10,0,0\"\u003e\u003cb data-path-to-node=\"0,10,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,10,1,0\"\u003e\u003cb data-path-to-node=\"0,10,1,0\" data-index-in-node=\"0\"\u003eMIMO\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• 5 GHz: 2 x 2 (DL\/UL MU-MIMO)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,10,2,1\"\u003e\n\u003cdiv\u003e• 2.4 GHz: 2 x 2 (DL\/UL MU-MIMO)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,11,1,0\"\u003e\u003cb data-path-to-node=\"0,11,1,0\" data-index-in-node=\"0\"\u003eMax. Data Rate\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• 5 GHz: 4.3 Gbps (BW240)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,11,2,1\"\u003e\n\u003cdiv\u003e• 2.4 GHz: 688 Mbps (BW40)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,12,1,0\"\u003e\u003cb data-path-to-node=\"0,12,1,0\" data-index-in-node=\"0\"\u003eAntenna Gain (5 GHz)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Directional internal (Built-in): 10 dBi, 95° × 45°\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,12,2,1\"\u003e\n\u003cdiv\u003e• Directional internal (Reflector Wide Angle): 11 dBi, 70° × 45°\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,12,2,3\"\u003e\n\u003cdiv\u003e• Directional internal (Reflector Narrow Angle): 12 dBi, 55° × 45°\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,12,2,5\"\u003e\n\u003cdiv\u003e• External omni: 6 dBi, 360° × 45°\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,13,1,0\"\u003e\u003cb data-path-to-node=\"0,13,1,0\" data-index-in-node=\"0\"\u003eAntenna Gain (2.4 GHz)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Directional internal (Built-in): 8 dBi, 100° × 45°\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,13,2,1\"\u003e\n\u003cdiv\u003e• Directional internal (Reflector Wide Angle): 9 dBi, 80° × 45°\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,13,2,3\"\u003e\n\u003cdiv\u003e• Directional internal (Reflector Narrow Angle): 10 dBi, 65° × 45°\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,13,2,5\"\u003e\n\u003cdiv\u003e• External omni: 5 dBi, 360° × 45°\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,14,1,0\"\u003e\u003cb data-path-to-node=\"0,14,1,0\" data-index-in-node=\"0\"\u003eMax. TX Power\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• 5 GHz: 24 dBm\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,14,2,1\"\u003e\n\u003cdiv\u003e• 2.4 GHz: 23 dBm\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,15,0,0\"\u003e\u003cb data-path-to-node=\"0,15,0,0\" data-index-in-node=\"0\"\u003eFeatures\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,15,1,0\"\u003e\u003cb data-path-to-node=\"0,15,1,0\" data-index-in-node=\"0\"\u003eWireless Features\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Wireless Meshing: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,1\"\u003e\n\u003cdiv\u003e• Band Steering: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,3\"\u003e\n\u003cdiv\u003e• 802.11v BSS Transition Management: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,5\"\u003e\n\u003cdiv\u003e• 802.11r Fast Roaming: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,7\"\u003e\n\u003cdiv\u003e• 802.11k Radio Resource Management (RRM): ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,9\"\u003e\n\u003cdiv\u003e• Advanced Radio Management: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,11\"\u003e\n\u003cdiv\u003e• Real-Time Spectral Analysis: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,13\"\u003e\n\u003cdiv\u003e• Passpoint (Hotspot 2.0): ✓\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,16,1,0\"\u003e\u003cb data-path-to-node=\"0,16,1,0\" data-index-in-node=\"0\"\u003eCaptive Hotspot Portal\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Custom Branding Landing Page: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,1\"\u003e\n\u003cdiv\u003e• Voucher Authentication: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,3\"\u003e\n\u003cdiv\u003e• Payment-Based Authentication: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,5\"\u003e\n\u003cdiv\u003e• External Portal Server Support: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,7\"\u003e\n\u003cdiv\u003e• Password Authentication: ✓\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,17,1,0\"\u003e\u003cb data-path-to-node=\"0,17,1,0\" data-index-in-node=\"0\"\u003eNetwork \u0026amp; Security\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Guest Network Isolation: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,17,2,1\"\u003e\n\u003cdiv\u003e• Private Pre-Shared Key (PPSK): ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,17,2,3\"\u003e\n\u003cdiv\u003e• WiFi Speed Limiting: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,17,2,5\"\u003e\n\u003cdiv\u003e• Client Device Isolation: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,17,2,7\"\u003e\n\u003cdiv\u003e• WiFi Schedules: ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,17,2,9\"\u003e\n\u003cdiv\u003e• RADIUS over TLS (RadSec): ✓\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,17,2,11\"\u003e\n\u003cdiv\u003e• Dynamic RADIUS-assigned VLAN: ✓\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,18,0,0\"\u003e\u003cb data-path-to-node=\"0,18,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,18,1,0\"\u003e\u003cb data-path-to-node=\"0,18,1,0\" data-index-in-node=\"0\"\u003eMax. Power Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,18,2,0\"\u003e13W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,19,1,0\"\u003e\u003cb data-path-to-node=\"0,19,1,0\" data-index-in-node=\"0\"\u003eSupported Voltage Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,19,2,0\"\u003e42.5–57V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,20,1,0\"\u003e\u003cb data-path-to-node=\"0,20,1,0\" data-index-in-node=\"0\"\u003eNetworking Interface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,20,2,0\"\u003e(1) 2.5 GbE RJ45 port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,21,1,0\"\u003e\u003cb data-path-to-node=\"0,21,1,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• Device: 577 g (1.3 lb)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,21,2,1\"\u003e\n\u003cdiv\u003e• Ball mount: 163 g (5.8 oz)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,21,2,3\"\u003e\n\u003cdiv\u003e• Reflector antenna set: 500 g (1.1 lb)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,21,2,5\"\u003e\n\u003cdiv\u003e• Omni antenna set: 52 g (1.8 oz)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,22,1,0\"\u003e\u003cb data-path-to-node=\"0,22,1,0\" data-index-in-node=\"0\"\u003eWind Loading\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,22,2,0\"\u003e97.3 N at 200 km\/h (21.9 lbf at 125 mph)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,23,1,0\"\u003e\u003cb data-path-to-node=\"0,23,1,0\" data-index-in-node=\"0\"\u003ePole Mount Diameter\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,23,2,0\"\u003e1–2.5\" (25–63.5 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,24,1,0\"\u003e\u003cb data-path-to-node=\"0,24,1,0\" data-index-in-node=\"0\"\u003eManagement\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,24,2,0\"\u003eEthernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,25,1,0\"\u003e\u003cb data-path-to-node=\"0,25,1,0\" data-index-in-node=\"0\"\u003eEnclosure Material\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,25,2,0\"\u003eUV-stabilized polycarbonate, aluminum alloy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,26,1,0\"\u003e\u003cb data-path-to-node=\"0,26,1,0\" data-index-in-node=\"0\"\u003eMount Material\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,26,2,0\"\u003eAluminum alloy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,27,1,0\"\u003e\u003cb data-path-to-node=\"0,27,1,0\" data-index-in-node=\"0\"\u003eLEDs\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e• System\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,27,2,1\"\u003e\n\u003cdiv\u003e• (4) Blue: signal\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,27,2,3\"\u003e\n\u003cdiv\u003e• (1) White\/Blue: indicator\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,28,1,0\"\u003e\u003cb data-path-to-node=\"0,28,1,0\" data-index-in-node=\"0\"\u003eAmbient Operating Temperature\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,28,2,0\"\u003e-40 to 70° C (-40 to 158° F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,29,1,0\"\u003e\u003cb data-path-to-node=\"0,29,1,0\" data-index-in-node=\"0\"\u003eAmbient Operating Humidity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,29,2,0\"\u003e5 to 95% noncondensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,30,1,0\"\u003e\u003cb data-path-to-node=\"0,30,1,0\" data-index-in-node=\"0\"\u003eNDAA Compliant\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,30,2,0\"\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,31,1,0\"\u003e\u003cb data-path-to-node=\"0,31,1,0\" data-index-in-node=\"0\"\u003eCertifications\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,31,2,0\"\u003eCE, FCC, IC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Ubiquiti","offers":[{"title":"Default Title","offer_id":67671587684501,"sku":"U7-Industrial","price":384.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/4983\/2085\/files\/42863mf9UDC.jpg?v=1791481833","url":"https:\/\/www.avexpress.net\/products\/ubiquiti-u7-industrial-access-point","provider":"AV Express","version":"1.0","type":"link"}