{"product_id":"ubiquiti-enterprise-campus-switch-core","title":"Ubiquiti Enterprise Campus Switch Core","description":"\u003cp\u003e\u003cstrong\u003eUbiquiti Enterprise Campus Switch Core\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e3.2 Tbps high-density 100G Layer 3 Etherlighting™ core switch with MC-LAG support for high availability system design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003csub\u003e\u003cb\u003e\u003cstrong class=\"lexical-bold lexical-subscript\"\u003eNote.\u003c\/strong\u003e\u003c\/b\u003e\u003cspan class=\"lexical-subscript\"\u003e Requires a 4-post rack, or a center-mount bracket or cantilever shelf on 2-post racks for optimal support.\u003c\/span\u003e\u003c\/sub\u003e\u003c\/p\u003e\n\u003cdiv class=\"markdown markdown-main-panel md-content enable-luminous-fast-follows enable-updated-hr-color tutor-markdown-rendering\" id=\"model-response-message-contentr_5e1606077bec3159\" dir=\"ltr\"\u003e\n\u003ctable data-path-to-node=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,1,0,0\"\u003e\u003cb data-path-to-node=\"0,1,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,1,1,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,1,2,0\"\u003e442.4 x 43.7 x 480 mm (17.4 x 1.7 x 18.9\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,2,0,0\"\u003e\u003cb data-path-to-node=\"0,2,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,2,1,0\"\u003ePort Layout\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e(1) GbE RJ45 (1G\/100M\/10M)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,2,2,1\"\u003e\n\u003cdiv\u003e(32) 100G QSFP28 (100G\/40G)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,2,2,3\"\u003e\n\u003cdiv\u003e(1) Console\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,3,0,0\"\u003e\u003cb data-path-to-node=\"0,3,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,3,1,0\"\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eMulti-Chassis Link Aggregation (MC-LAG)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,3,2,1\"\u003e\n\u003cdiv\u003e(2) Hot-Swappable PSUs\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,3,2,3\"\u003e\n\u003cdiv\u003e(5) Hot-Swappable Fans\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,4,0,0\"\u003e\u003cb data-path-to-node=\"0,4,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,4,1,0\"\u003eLayer 3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,4,2,0\"\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,5,0,0\"\u003e\u003cb data-path-to-node=\"0,5,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,5,1,0\"\u003eForm Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,5,2,0\"\u003eRack Mount (1U, Full-Depth)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,6,0,0\"\u003e\u003cb data-path-to-node=\"0,6,0,0\" data-index-in-node=\"0\"\u003eOverview\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,6,1,0\"\u003eEtherlighting™\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,6,2,0\"\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,7,0,0\"\u003e\u003cb data-path-to-node=\"0,7,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,7,1,0\"\u003eSwitching Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,7,2,0\"\u003e6.4 Tbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,8,0,0\"\u003e\u003cb data-path-to-node=\"0,8,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,8,1,0\"\u003eTotal Non-Blocking Throughput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,8,2,0\"\u003e3.2 Tbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,9,0,0\"\u003e\u003cb data-path-to-node=\"0,9,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,9,1,0\"\u003eForwarding Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,9,2,0\"\u003e2.8 Bpps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,10,0,0\"\u003e\u003cb data-path-to-node=\"0,10,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,10,1,0\"\u003eSupported VLANs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,10,2,0\"\u003e1,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,11,0,0\"\u003e\u003cb data-path-to-node=\"0,11,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,11,1,0\"\u003eMAC Address Table Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,11,2,0\"\u003e128,000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,12,0,0\"\u003e\u003cb data-path-to-node=\"0,12,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,12,1,0\"\u003eIPv4 Static Routes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,12,2,0\"\u003e256\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,13,0,0\"\u003e\u003cb data-path-to-node=\"0,13,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,13,1,0\"\u003ePacket Buffer Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,13,2,0\"\u003e24 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,14,0,0\"\u003e\u003cb data-path-to-node=\"0,14,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,14,1,0\"\u003eAccess Lists\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eIPv4: 512\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,14,2,1\"\u003e\n\u003cdiv\u003eMAC: 512\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,15,0,0\"\u003e\u003cb data-path-to-node=\"0,15,0,0\" data-index-in-node=\"0\"\u003eLayer 3 Features\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,15,1,0\"\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eDHCP Server (Local Networks)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,1\"\u003e\n\u003cdiv\u003eDHCP Relay\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,3\"\u003e\n\u003cdiv\u003eInter-VLAN Routing (Local Networks)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,15,2,5\"\u003e\n\u003cdiv\u003eStatic Routing (Local Networks)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,16,0,0\"\u003e\u003cb data-path-to-node=\"0,16,0,0\" data-index-in-node=\"0\"\u003eLayer 2 Features\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,16,1,0\"\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eLACP Port Aggregation\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,1\"\u003e\n\u003cdiv\u003eMC-LAG\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,3\"\u003e\n\u003cdiv\u003eSTP \u0026amp; RSTP\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,5\"\u003e\n\u003cdiv\u003eAdvanced IGMP Configuration (Querier, Fast Leave, Router Port)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,7\"\u003e\n\u003cdiv\u003eIGMP Snooping\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,9\"\u003e\n\u003cdiv\u003eMAC-Based ACLs \u0026amp; Device Isolation\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,11\"\u003e\n\u003cdiv\u003eDHCP Snooping \u0026amp; Guarding\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,13\"\u003e\n\u003cdiv\u003eEgress Rate Limit\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,15\"\u003e\n\u003cdiv\u003eFlow Control\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,17\"\u003e\n\u003cdiv\u003eMAC Address Blocking\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,19\"\u003e\n\u003cdiv\u003eIP-Based ACLs \u0026amp; Network Isolation\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,21\"\u003e\n\u003cdiv\u003eMAC-Based Port Restriction\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,23\"\u003e\n\u003cdiv\u003ePort Isolation\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,25\"\u003e\n\u003cdiv\u003ePort Mirroring\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,27\"\u003e\n\u003cdiv\u003eJumbo Frames\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,29\"\u003e\n\u003cdiv\u003eLLDP-MED\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,31\"\u003e\n\u003cdiv\u003eVoice VLAN\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,16,2,33\"\u003e\n\u003cdiv\u003eLoop Protection\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,17,0,0\"\u003e\u003cb data-path-to-node=\"0,17,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,17,1,0\"\u003eMax. Power Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,17,2,0\"\u003e360W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,18,0,0\"\u003e\u003cb data-path-to-node=\"0,18,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,18,1,0\"\u003ePower Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,18,2,0\"\u003e(2) Universal input, 100–240V AC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,19,0,0\"\u003e\u003cb data-path-to-node=\"0,19,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,19,1,0\"\u003ePower Input Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,19,2,0\"\u003e(2) AC input, Hot-swappable power modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,20,0,0\"\u003e\u003cb data-path-to-node=\"0,20,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,20,1,0\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,20,2,0\"\u003e(2) Hot-swappable AC\/DC 550W power modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,21,0,0\"\u003e\u003cb data-path-to-node=\"0,21,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,21,1,0\"\u003eSupported Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,21,2,0\"\u003e100–240V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,22,0,0\"\u003e\u003cb data-path-to-node=\"0,22,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,22,1,0\"\u003eManagement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,22,2,0\"\u003eEthernet, AR, Serial Console\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,23,0,0\"\u003e\u003cb data-path-to-node=\"0,23,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,23,1,0\"\u003eHeat Dissipation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,23,2,0\"\u003e1,228 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,24,0,0\"\u003e\u003cb data-path-to-node=\"0,24,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,24,1,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eWithout mounting brackets: 9.7 kg (21.4 lb)\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,24,2,1\"\u003e\n\u003cdiv\u003eWith mounting brackets: 9.8 kg (21.6 lb)\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,25,0,0\"\u003e\u003cb data-path-to-node=\"0,25,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,25,1,0\"\u003eEnclosure Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,25,2,0\"\u003eSGCC steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,26,0,0\"\u003e\u003cb data-path-to-node=\"0,26,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,26,1,0\"\u003eMount Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,26,2,0\"\u003eSGCC steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,27,0,0\"\u003e\u003cb data-path-to-node=\"0,27,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,27,1,0\"\u003eSupported Rack Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e482.6 mm (19\") four-post racks\u003c\/div\u003e\n\u003cbr\u003e\u003cbr data-path-to-node=\"0,27,2,1\"\u003e\n\u003cdiv\u003ePosts depths ranging from 650 to 1,000 mm (25.6–39.4”)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,28,0,0\"\u003e\u003cb data-path-to-node=\"0,28,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,28,1,0\"\u003eLCM Display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,28,2,0\"\u003e1.3\" touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,29,0,0\"\u003e\u003cb data-path-to-node=\"0,29,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,29,1,0\"\u003eFan Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,29,2,0\"\u003e(5) Hot-swappable fan modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,30,0,0\"\u003e\u003cb data-path-to-node=\"0,30,0,0\" data-index-in-node=\"0\"\u003eHardware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,30,1,0\"\u003eESD Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,30,2,0\"\u003eAir: ± 12KV; contact: ± 8KV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,31,0,0\"\u003e\u003cb data-path-to-node=\"0,31,0,0\" data-index-in-node=\"0\"\u003eEnvironmental\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,31,1,0\"\u003eAmbient Operating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,31,2,0\"\u003e-5 to 40° C (23 to 104° F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,32,0,0\"\u003e\u003cb data-path-to-node=\"0,32,0,0\" data-index-in-node=\"0\"\u003eEnvironmental\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,32,1,0\"\u003eAmbient Operating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,32,2,0\"\u003e10 to 90% noncondensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,33,0,0\"\u003e\u003cb data-path-to-node=\"0,33,0,0\" data-index-in-node=\"0\"\u003eEtherlighting™\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,33,1,0\"\u003eSupported Optics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,33,2,0\"\u003eQSFP28 ✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,34,0,0\"\u003e\u003cb data-path-to-node=\"0,34,0,0\" data-index-in-node=\"0\"\u003eLEDs\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,34,1,0\"\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,34,2,0\"\u003eEthernet ✓, PSU ✓, Fan ✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,35,0,0\"\u003e\u003cb data-path-to-node=\"0,35,0,0\" data-index-in-node=\"0\"\u003eCompliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,35,1,0\"\u003eNDAA Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,35,2,0\"\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,36,0,0\"\u003e\u003cb data-path-to-node=\"0,36,0,0\" data-index-in-node=\"0\"\u003eCompliance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,36,1,0\"\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,36,2,0\"\u003eCE, FCC, IC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,37,0,0\"\u003e\u003cb data-path-to-node=\"0,37,0,0\" data-index-in-node=\"0\"\u003eSoftware\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,37,1,0\"\u003eApplication Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"0,37,2,0\"\u003eUniFi Network Version 10.6.101 and later\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Ubiquiti","offers":[{"title":"Default Title","offer_id":67671899177109,"sku":"ECS-Core","price":5508.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0672\/4983\/2085\/files\/Screenshot2026-10-08at2.12.21PM.png?v=1791486767","url":"https:\/\/www.avexpress.net\/products\/ubiquiti-enterprise-campus-switch-core","provider":"AV Express","version":"1.0","type":"link"}